The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes
    • The Product Book

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data and AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma and Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
    • Content Hubs
Subscribe
Subscribe

False

The Analytical Scientist / Issues / 2026 / November / A Faster Route to Antibody Peptide Maps
Mass Spectrometry Clinical News and Research

A Faster Route to Antibody Peptide Maps

Researchers use direct-infusion mass spectrometry to analyze 96 antibody samples in about two hours

11/18/2026 2 min read
  • Full Article
  • Summary
  • Listen
  • Scorecard
  • Quiz
  • Poll

Share

A direct-infusion mass spectrometry workflow could reduce the time required to map monoclonal antibody peptides by as much as 100-fold, according to a study.

The method, called RaPiD-mAb-MS, replaces liquid chromatography with automated nanoelectrospray infusion. It combines 96-well plate sample preparation, high-resolution mass spectrometry, and software that automates peptide matching and modification analysis.

Researchers from the University of Wisconsin-Madison, the Morgridge Institute for Research, and several pharmaceutical companies reported that the workflow can process 96 samples in approximately 1.5 to two hours. The mass spectrometry method takes about 60 seconds per sample, with a total sample-to-sample cycle of roughly two minutes. Conventional LC-MS peptide mapping can require considerably longer separations, column equilibration, and blank runs.

Sample preparation involves antibody reduction, alkylation, precipitation, washing, and tryptic digestion within a filter plate. The resulting peptides are transferred to a second plate and infused by an automated nanoelectrospray system into a high-resolution Orbitrap mass spectrometer. Preparation takes approximately four hours.

Across more than 1,500 experiments involving 28 monoclonal antibody sequences, the workflow achieved median sequence coverage of 100 percent and mean coverage of 97.7 percent. In one test, it provided complete coverage for antibodies based on nirsevimab and semorinemab sequences and approximately 95 percent coverage for molecules based on clesrovimab.

The researchers also evaluated the method’s ability to measure attributes relevant to antibody development. RaPiD-mAb-MS detected oxidation, deamidation, glycosylation, terminal modifications, sequence variants, and antibody-drug conjugation sites. Oxidation measurements from forced-degradation studies correlated closely with conventional LC-MS results.

Stable isotope-labeled peptides indicated an average detection limit of approximately 0.7 percent relative abundance, with results ranging from 0.2 to 1.2 percent depending on the peptide. This sensitivity is lower than targeted LC-MS/MS can provide for some low-abundance species.

Removing chromatography presents additional challenges. Deamidated peptides can overlap with their unmodified counterparts, requiring high-resolution targeted MS/MS. Isoaspartate cannot be detected directly because it is isobaric with aspartate, so the researchers added an optional enzymatic labeling step to create a measurable mass shift.

To demonstrate higher-throughput use, the team analyzed 1,152 forced-degradation samples in about 35.5 hours. The resulting data were used to compare formulation conditions and modification patterns across antibodies.

The authors position the method primarily for discovery, formulation screening, and process development. Conventional LC-MS remains important for ultratrace detection and established regulated quality-control workflows. Further method-specific qualification would be required before direct infusion could support regulated testing.

Newsletters

Receive the latest analytical science news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

False

Advertisement

Recommended

False

Related Content

 This Week’s Mass Spec News
Mass Spectrometry
This Week’s Mass Spec News

April 4, 2025

2 min read

 What If Computers Could Smell?
Mass Spectrometry
What If Computers Could Smell?

April 3, 2025

13 min read

Computers can “see” and “hear,” but fully digitizing scent has so far eluded science – but that may soon change

The Analytical Scientist Innovation Awards 2024: #6
Mass Spectrometry
The Analytical Scientist Innovation Awards 2024: #6

December 3, 2024

3 min read

Syft Technologies’ William Pelet introduces the Syft Explorer – the world's first fully mobile, real-time, and direct trace gas analyzer

The Analytical Scientist Innovation Awards 2024: #4
Mass Spectrometry
The Analytical Scientist Innovation Awards 2024: #4

December 5, 2024

6 min read

Thermo Fisher Scientific’s high-sensitivity mass spec for translational omics research – the Stellar MS – is ranked 4th in our annual Innovation Awards

Affiliations:

Specialties:

Areas of Expertise:

Contributions:

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Your Privacy Choices
  • Advertise With Us
  • Contact Us

Copyright © 2026 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.