Conexiant
Login
  • The Analytical Scientist
  • The Cannabis Scientist
  • The Medicine Maker
  • The Ophthalmologist
  • The Pathologist
  • The Traditional Scientist
The Analytical Scientist
  • Explore

    Explore

    • Latest
    • News & Research
    • Trends & Challenges
    • Keynote Interviews
    • Opinion & Personal Narratives
    • Product Profiles
    • App Notes

    Featured Topics

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy

    Issues

    • Latest Issue
    • Archive
  • Topics

    Techniques & Tools

    • Mass Spectrometry
    • Chromatography
    • Spectroscopy
    • Microscopy
    • Sensors
    • Data & AI

    • View All Topics

    Applications & Fields

    • Clinical
    • Environmental
    • Food, Beverage & Agriculture
    • Pharma & Biopharma
    • Omics
    • Forensics
  • People & Profiles

    People & Profiles

    • Power List
    • Voices in the Community
    • Sitting Down With
    • Authors & Contributors
  • Business & Education

    Business & Education

    • Innovation
    • Business & Entrepreneurship
    • Career Pathways
  • Events
    • Live Events
    • Webinars
  • Multimedia
    • Video
Subscribe
Subscribe

False

The Analytical Scientist / Issues / 2014 / Nov / Time Saving, High Resolution GPC/SEC Using Micro Columns and Optimized RI Detection
Sponsored

Time Saving, High Resolution GPC/SEC Using Micro Columns and Optimized RI Detection

As in HPLC before there is now a trend in GPC/SEC to separate low molar mass polymers and oligomers on columns filled with small particles.

11/24/2014 1 min read

Sponsored By

Share

Smaller particles are used to obtain higher resolution. If these particles are packed in GPC/SEC columns with smaller inner diameters (compared to traditional analytical columns) an efficient separation can be achieved that needs less mobile phase. Traditionally micro columns are run at a reduced flow-rate of 0.35 ml/min, but modern materials can be also operated in the flow-rate range of 0.5 - 0.7 mL/min to save not only mobile phase, but also time. Typical column dimensions for micro columns are e.g. 150 to 250 mm length and 4.6 mm inner diameter.

12314-app-note-PSS-logo

Unlike in UHPLC, in μGPC/SEC it is not the extremely high pressures that are a challenge but the cell volumes of the typical GPC/SEC detectors. If the cell volume is too large, the previously separated oligomers will be back-mixed in the detector cell and the advantage of small particle sizes and dedicated micro columns is lost. Cells with small volumes are already available for many UV/DAD, however for the most common GPC/SEC detector, the refractive index RI, only very few models are suitable. With the PSS SECcurity µRI an RI with the smallest cell volume (1.7 μL), specifically designed for use with micro columns is now available. The detector can be seamlessly retrofitted at any time in PSS SECcurity GPC systems as well as in Agilent 1260/1290-Systems.

For this application note, PSS SDV columns, a polymeric crosslinked styrene-divinyl benzene material, have been used to investigate the resolution and the performance of the PSS µRI for oligomeric polystyrene. An advantage of polymeric stationary phases over silica based materials is that less interactions are observed. In addition, it is easier to construct a column set that is mismatch free to cover a wider molar mass range.

1114-701-PSS-fig1Figure 1. Oligomeric polystyrene separated in < 3 mL on PSS SDV micro column with 3 µm particle size using an analytical SECcurity RI (blue trace) and a SECcurity µRI (green trace)

Figure 1 shows a comparison of the separation of an oligomeric polystyrene on two polymer based PSS SDV micro columns with small particles using a analytical SECcurity RI with 8 µL cell and the PSS µRI with a 1.7 µL cell. Although the analytical RI already has very good performance, it is possible to detect more oligomers with the µRI detector. In addition to the higher resolution, the µRI detector also shows less signal broadening. Figure 2 shows a magnified comparison of the two traces for Peak F – it is clearly visible that the peak for the µRI is narrower.

1114-701-PSS-fig2Figure 2. Comparison of dimeric styrene measured on micro columns with an analytical SECcurity RI (blue trace) and a µRI (green trace).

Website: www.pss-polymer.com

Newsletters

Receive the latest analytical science news, personalities, education, and career development – weekly to your inbox.

Newsletter Signup Image

False

Advertisement

Recommended

False

False

The Analytical Scientist
Subscribe

About

  • About Us
  • Work at Conexiant Europe
  • Terms and Conditions
  • Privacy Policy
  • Advertise With Us
  • Contact Us

Copyright © 2025 Texere Publishing Limited (trading as Conexiant), with registered number 08113419 whose registered office is at Booths No. 1, Booths Park, Chelford Road, Knutsford, England, WA16 8GS.